Battery added proper initialization for the capacity voltage fusion and doubled the time constant

parent 663913a1
No related branches found
No related tags found
No related merge requests found
......@@ -59,7 +59,7 @@ Battery::Battery() :
_discharged_mah_loop(0.f),
_remaining_voltage(1.f),
_remaining_capacity(1.f),
_remaining(1.f),
_remaining(2.f),
_scale(1.f),
_warning(battery_status_s::BATTERY_WARNING_NONE),
_last_timestamp(0)
......@@ -191,9 +191,15 @@ Battery::estimateRemaining(float voltage_v, float current_a, float throttle_norm
_remaining_capacity = math::max(1.f - _discharged_mah / _capacity.get(), 0.f);
// if battery capacity is known, fuse voltage measurement with used capacity
_remaining = 0.999f * _remaining + 0.001f * _remaining_voltage;
_remaining -= _discharged_mah_loop / _capacity.get();
_remaining = math::max(_remaining, 0.f);
if (_remaining > 1.f) {
// initialization of the state
_remaining = _remaining_voltage;
} else {
_remaining = 0.9995f * _remaining + 0.0005f * _remaining_voltage;
_remaining -= _discharged_mah_loop / _capacity.get();
_remaining = math::max(_remaining, 0.f);
}
} else {
// else use voltage
......
0% Loading or .