Newer
Older
# Changelog
All notable changes to Pulselib will be documented in this file.
## \[1.5.4] - 2022-08-@@@
### Fixed
- Fixed set_acquisition with t_measure and sample_rate
## \[1.5.3] - 2022-08-05
### Fixed
- Fixed looping and HVI marker
- Added retries to sequence upload and play
Sander de Snoo
committed
## \[1.5.2] - 2022-08-03
### Fixed
- sequencer.get_channel_data and get_measurement_param when using play() with index
as done by core-tools.
## \[1.5.1] - 2022-08-03
### Added
- Added sequencer.plot()
### Fixed
- Fixed looping t_off of add_HVI_marker
- Fixed plotting after mk_sequence
- Added sequencer.get_measurement_param with automatic upload/play and thresholding
- Added sequencer.get_measurement_results
- Added channel acquire(..., n_repeat= , interval= )
- Added digitizer configuring by M3202A_Uploader.
### Changed
- Default channel offset is None to allow configuration outside of pulselib
### Fixed
- Scaling of custom pulses with virtual gates. Custom function now always called with amplitude of original pulse.
- Renamed Tektronix backend 'Tektronix_5014' after refactoring:
- Faster and allow fast switching between multiple uploaded sequences.
- Amplitude output has been corrected. It is 2x previous output. Correct attenuation per channel!!
- Use sequence.play(release=False) to call play multiple times after a single upload.
- Use infinite looping when n_rep > 65535
- Added sequencer.repetition_aligment to align the duration of the sequence with an external clock or signal frequency.
(currently only implemented for Tektronix)
Sander de Snoo
committed
## \[1.3.5] - 2022-03-29
### Fixed
- Error when rendering section with low sample rate extends into segment with high sample rate.
## \[1.3.4] - 2022-03-23
### Improved
- QuantumSequencer use waveform with low sample rate for long DC compensation pulse.
### Fixed
- Fixed long wait (> 160 ms) for QuantumSequencer
### Added
- Added attribute 'values' to sequence loop parameters
## \[1.3.1] - 2022-03-07
### Fixed
- Fixed rendering of segments with different sample rates
- Rendering of conditional segments with looping
### Added
- IQ correction of phase, amplitude and offset:
add_channel_offset, set_qubit_correction_phase, set_qubit_correction_gain
- New interface from hardware class to pulselib: set_channel_attenuations and add_virtual_matrix
- Virtual matrix on top of virtual gates
### Removed
- pulse.add_channel_compenstation_limit. Correct method is add_channel_compensation_limit
### Fixed
- loops with t_measurement in HVI variable.
- release_awg_memory() for Keysight
## \[1.2.0] - 2021-11-11
First labeled release. Start of dev branch and change logging.