# Changelog
All notable changes to Pulselib will be documented in this file.
## \[1.6.15] - 2023-03-06
- Fixed rounding errors on segment boundaries in Qblox uploader.
- Qblox uploader assign IQ marker to sequencer of first qubit on IQ output.
- Refactored IQ channel definition: pulse_lib.define_iq_channel()
- Added lp.arange() similar to numpy.arange()
## \[1.6.14] - 2023-03-03
- Fixed missing IQ marker around chirp
## \[1.6.13] - 2023-03-01
- Fixed MeasurementMajority to work with pulse_templates.
- Fixed DC compensation on Qblox.
- Fixed some edge cases.
Sander Snoo
committed
- QuantumSequencer: split long constant waveforms in start and stop waveform.
## \[1.6.11] - 2023-02-17
- Fixed measurement parameter for acquisition with accept_if not None
## \[1.6.10] - 2023-02-13
- Round acquisition time towards zero in uploader
- Fix for measurement expressions in sequence
- Fix for simultaneous driving
- Fixed majority vote in expression
## \[1.6.9] - 2023-02-06
- Fixed acquire wait=True with n_repeat
- Added checks on t_measure and sample rate in read_channels.
- Fixed actual number of points and interval for acquisition:
n_samples, interval = uploader.actual_acquisition_points(acquisition_channel, t_measure, sample_rate)
- Replaced logging by logger
## \[1.6.8] - 2023-02-02
- Fixed setpoints of measurement parameter for time traces > 2 seconds.
- Fixed simultaneous pulses with indexing of segments on looping parameter.
- Calculate timeout for get_acquisition_data from sequence.
## \[1.6.7] - 2023-02-01
- Added continuous mode for Keysight AWG.
## \[1.6.6] - 2023-01-30
- Fixed errors when slicing segments after adding dimension with update_dim.
- Remove phase shifts of 0.0 rad before rendering.
- Fixed error in KeysightQS with phase-shift after MW pulse.
- Added tests.utils.last_upload.get_last_upload to analyze upload after exception
- Fixed numpy deprecation of np.int and np.float.
### Fixed
- Qblox uploader overlapping pulses error
### Added
- parameter iq_mode to sequencer.get_measurement_parameter(), get_measurement_data(), Qblox fast scan
- read_channels() to read digitizer channels without pulsing AWG. (Currently Qblox only)
- Keysight AWG mock rendering at 10 GSa/s using digital filter setting.
- acquire(... wait=True) to add wait time for acquisition.
### Fixed
- Timing of Keysight_QS with 2022 firmware
- Keysight_QS rf_source bug
- Fixed n_samples in measurement_param
- Fixed Qblox sequence generation when no pulses on AWG channels
### Removed
- get_acquisition_param. It was deprecated for quite some time.
## \[1.6.2] - 2022-12-22
### Added
- pulselib.get_channel_attenuations()
### Changed
- Sequencer upload and play only retry upload after specific Keysight exception.
- Chirp is stored as an instruction to be rendered by backend.
## \[1.6.1] - 2022-12-06
### Added
- start_times to measurement_description
### Changed
- measurement names do not have to be unique. A postfix makes them unique.
### Attention !!
- Digitizer trigger timing has been corrected for channel delays !!
- Digitizer RF source API has changed.
- Looping has been refactored to add functionality and improve performance.
- Important internal interface changes are marked with [v1.6.0] in the code.
### Added
- Added segment_container.update_dim for looping with index
- Added numpy array operations to looping variables
- Added looping.array to loop over an arbitrary array of values
- Added digitizer_channel.delay
- Added `prolongation_ns` to RF source configuration
- Added `iq_complex` to fast_scan1D_param and fast_scan2D_param
### Changed
- Changed set_digitizer_rf_source `trigger_offset_ns` to `startup_time_ns`.
- Refactored looping and segment indexing:
- Improved performance of looping arguments
- Improved performance of segment_container.reset_time()
- Improved performance of segment and segment_container indexing
- Improved performance of sequence pre-rendering
- Reduced memory usage
- Added sanity checks on looping arguments
- Added checks on frequency when rendering MW pulses
### Removed
- Removed segment_container append(), slice_time(), last_edit
### Fixed
- Fixed addition of 2 segment_containers to construct simultaneous driving
- Tektronix marker on unused AWG channel
- Measurement result inversion with zero_on_high
- Multiple measurements on 1 channel with down-sampling
## \[1.5.6] - 2022-10-10
### Fixed
- Fixed error in measurement parameter when no shot is accepted
## \[1.5.5] - 2022-09-27
### Fixed
- Incorrect setpoints in measurement_param.add_derived_param.
### Added
- Added endpoint to looping.linspace, logspace and geomspace.
- Added more data selection options to get_measurement_results()
Sander Snoo
committed
- Added addition of segment_containers to construct simultaneous driving
- Added sequence_builder.add_simultaneous()
### Changed
- Do not add axis 'repetition' if sequencer.n_rep == None.
### Fixed
- Fixed set_acquisition with t_measure and sample_rate
- Fixed high memory usage due to unlimited waveform cache.
## \[1.5.3] - 2022-08-05
### Fixed
- Fixed looping and HVI marker
- Added retries to sequence upload and play
Sander de Snoo
committed
## \[1.5.2] - 2022-08-03
### Fixed
- sequencer.get_channel_data and get_measurement_param when using play() with index
as done by core-tools.
## \[1.5.1] - 2022-08-03
### Added
- Added sequencer.plot()
### Fixed
- Fixed looping t_off of add_HVI_marker
- Fixed plotting after mk_sequence
- Added sequencer.get_measurement_param with automatic upload/play and thresholding
- Added sequencer.get_measurement_results
- Added channel acquire(..., n_repeat= , interval= )
- Added digitizer configuring by M3202A_Uploader.
### Changed
- Default channel offset is None to allow configuration outside of pulselib
### Fixed
- Scaling of custom pulses with virtual gates. Custom function now always called with amplitude of original pulse.
- Renamed Tektronix backend 'Tektronix_5014' after refactoring:
- Faster and allow fast switching between multiple uploaded sequences.
- Amplitude output has been corrected. It is 2x previous output. Correct attenuation per channel!!
- Use sequence.play(release=False) to call play multiple times after a single upload.
- Use infinite looping when n_rep > 65535
- Added sequencer.repetition_aligment to align the duration of the sequence with an external clock or signal frequency.
(currently only implemented for Tektronix)
Sander de Snoo
committed
## \[1.3.5] - 2022-03-29
### Fixed
- Error when rendering section with low sample rate extends into segment with high sample rate.
## \[1.3.4] - 2022-03-23
### Improved
- QuantumSequencer use waveform with low sample rate for long DC compensation pulse.
### Fixed
- Fixed long wait (> 160 ms) for QuantumSequencer
### Added
- Added attribute 'values' to sequence loop parameters
## \[1.3.1] - 2022-03-07
### Fixed
- Fixed rendering of segments with different sample rates
- Rendering of conditional segments with looping
### Added
- IQ correction of phase, amplitude and offset:
add_channel_offset, set_qubit_correction_phase, set_qubit_correction_gain
- New interface from hardware class to pulselib: set_channel_attenuations and add_virtual_matrix
- Virtual matrix on top of virtual gates
### Removed
- pulse.add_channel_compenstation_limit. Correct method is add_channel_compensation_limit
### Fixed
- loops with t_measurement in HVI variable.
- release_awg_memory() for Keysight
## \[1.2.0] - 2021-11-11
First labeled release. Start of dev branch and change logging.